1140V (160KW~600KW)

額定功率(KW) 132 160
185 220
250 280 315
400
Rating Output Current(A) 155 179 207
250 280 313 352 448
Rating Input Current(A) 137
161 186
225
252 282 317 402
AC Input Voltage(V) 1140Vac +/- 20%
Input Frequency 48 ~ 62 Hz
AC Output Voltage 0 to input voltage
AC Output Frequency 0 ~ 200 Hz
Overload 150% , continuous 1 minute
Control System Sensorless flux Vector , Sine coded PWM
Frequency Resolution 0.10%
Frequency Linearity 0.2% of maximum frequency
Communications BACNET, Profibus, Modbus, lonWorks,
Metasys via RS-485 (option)
Accel & Decel Time Independent Accel & Decel adjustment with S-curve
Analogue Input/Output 0~5V , 0~10V ; 0~20mA , 4~20mA
Digital Input 5 Digital input with programmable control functionality
Relay Output 2 relays type NO / NC with programmable functionality
Local Control Comprehensive local control include
Start (FWD/REV) , Stop , Reset , and Set Speed
Display Screen 16 character*2 line alphanumeric , Backlight and auto contrast .
Run Variables Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature
, I2t used process variable scale
Protection Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature
Operating Temperature 0 ~ 40℃

660V (132KW~600KW)

額定功率(KW) 132 160 185 220 250 280 315 400 600
Rating Output Current(A) 155 179 207 250 280 313 352 448 671
Rating Input Current(A) 137 161 186 225 252 282 317 402 604
AC Input Voltage(V) 660Vac +/- 20%
Input Frequency 48 ~ 62 Hz
AC Output Voltage 0 to input voltage
AC Output Frequency 0 ~ 200 Hz
Overload 200% , continuous 1 minute
Control System Sensorless flux Vector , Sine coded PWM
Frequency Resolution 0.10%
Frequency Linearity 0.2% of maximum frequency
Communications BACNET, Profibus, Modbus, lonWorks, Metasys via RS-485 (option)
Accel & Decel Time Independent Accel & Decel adjustment with S-curve
Analogue Input/Output 0~5V , 0~10V ; 0~20mA , 4~20mA
Digital Input 5 Digital input with programmable control functionality
Relay Output 2 relays type NO / NC with programmable functionality
Local Control Comprehensive local control include Start (FWD/REV) , Stop , Reset , and Set Speed
Display Screen 16 character*2 line alphanumeric , Backlight and auto contrast .
Run Variables Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature , I2t used process variable scale
Protection Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature
Operating Temperature 0 ~ 40℃

380V (15KW~450KW)

額定功率(KW) 15 20 30 45 55 75 90 132 185 220 250 315 400 450
Rating Output Current(A) 30 40 57 88 109 140 170 260 360 430 490 610 780 875
Rating Input Current(A) 27 36 54 81 99 135 162 237 333 395 449 566 719 808
AC Input Voltage(V) 380Vac +/- 20%
Input Frequency 48 ~ 62 Hz
AC Output Voltage 0 to input voltage
AC Output Frequency 0 ~ 200 Hz
Overload 1250%
Control System Sensorless flux Vector , Sine coded PWM
Frequency Resolution 0.10%
Frequency Linearity 0.2% of maximum frequency
Communications BACNET, Profibus, Modbus, lonWorks, Metasys via RS-485 (option)
Accel & Decel Time Independent Accel & Decel adjustment with S-curve
Analogue Input/Output 0~5V , 0~10V ; 0~20mA , 4~20mA
Digital Input 5 Digital input with programmable control functionality
Relay Output 2 relays type NO / NC with programmable functionality
Local Control Comprehensive local control include Start (FWD/REV) , Stop , Reset , and Set Speed
Display Screen 16 character*2 line alphanumeric , Backlight and auto contrast .
Run Variables Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature , I2t used process variable scale
Protection Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature
Operating Temperature 0 ~ 40℃